How are the Current graphics applied, wrap?
The window delivery side is just decals and are removed easily with a heat gun along with decals on the front of the truck.
The opposite side where the drivers door is just a heavy duty banner taped in place. We were not sure if we wanted a name change down the road and this allowed us to make the change easy and much less expensively that installing a wrap which we have used in the past on other vehicles.
Could it pass a Monroe county New York health and fire test?
This truck is licensed and inspected by NYS and has passed in multiple jurisdictions, EG Glens Falls and Oneonta offices. The only fire dept inspection was done at the Saratoga Racetrack by the the NYS Fire Marshall and the NYRA Fire Marshal. Because we did not have an ansul system for the deep fryer, they had us disconnect the gas to that appliance.
Could a small stove fit below griddle?
Not below but there is room on the 48" stainless steel table. Griddle/flatop is 36" and you can get a two burner stove top that is 12" wide.
What is exterior length?
18' without the front generator(s) holding cage/bracket.
Does the water heater have the pressure relieve valve plumbed to the exterior with CPVC or Copper with the pipe being the same size as the outlet?
Pressure relief valve is not plumbed to the outside with any size pipe. As is the case with every other food truck or even RV in NYS.
Does the water heater have a minimum of 18” metal flex line to the first connection of conveyance pipe?
No, the connections are all PVC pipe as required by NYS.
Are the water lines an approved water line such as PEX, CPVC or Copper. Not vinyl, braided, soda fountain pipe etc?
Hard PVC pipe is used for all fittings except the vinyl braided line that feeds the hand wash station.
Does the electrical panel have a main breaker that shuts off the system?
Does the electrical panel have a clear access of 24” x 30” in front of it? There can be no tables, appliances, countertops etc. in front of the panel area (cannot reach over).
In keeping with local code requirements, the local Fire Marshall, the NYS Fire Marshall and the NYRA (New York Racing Association) Fire Marshall, this set up meets all codes and inspections.
Is the main door a minimum of 28” wide and 72” tall?
How many AMPs is the main electrical system? as allowed are 120V single main with up to (5) branch breakers. – 50 AMP can be over 5 branch circuits.
Main connections to truck is #8 wire bringing in 50 amps.
I see that your shore power is listed as standard 20 Amp plugs. 20 AMP or 15 AMP branch breakers can be used. 20 AMP must use 12 AWG conductors (wire) and 15 AMP use 14 AWG or 12 AWG. Do they?
With the 50 amp service, all circuits are 12AWG wire.
Is the exposed wall adjacent to the cooking top 50 flame-spread or less?
The cook top wall is stainless steel and separated about 2 inches from the next wall.